Filter Results By:

Products

Applications

Manufacturers

Current Transformer Test

measures insulation, excitation current, turns ratio, winding polarity saturation and/or winding resistance. Current Transformers

See Also: Transformer Test, Transformer Testers, Current Transformer Test Set


Showing results: 106 - 120 of 173 items found.

  • Primary Test Equipment

    LET-400-RD - EUROSMC, S.A.

    It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.

  • Digital LOOP/PSC/EARTH Tester

    1824 LP - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.

  • Oil Immersed Test Transformer

    SG-YD - Wuhan Sangao Electrical Test Installations Limit Co.

    AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • CT/VT Test System

    Eltel Industries

    Fully pre-wired comprehensive turn test system. *Suitable for CTs up to 6000A & VTs up to 132kV. * Precision to (0.005 class) internal multi-ratio standard CT. * Internal 4KA current source. * State-of-the-art Instrument Transformer Test Set AITTS-98 with computer & printer interfaces. * Electronic potential divider facilitates testing any VT ratio upto 132kV. * Current & potential burdens.

  • Three Phase Power Calibrators And Tester Of Power Engineering Devices

    C300B - Calmet Smart Calibration Devices

    Three phase, class 0.02 and 0.05 power quality calibrator up to 120A (360A) and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.

  • Digital Electrical Network Analyzer

    1826 NA - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.

  • FTL Test Block

    SecuControl inc.

    FTL testblock with dust cover and current disconnect pinThe FTL is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters, ... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTL test block uses disconnect pins to isolate the substation devices from the system side equipment. Once isolated, secondary injection can be performed using banana jacks on the front side of the test block.

  • Resistance Measurement

    PROMET - KoCoS Messtechnik AG

    High-precision micro-ohm measuring systems with adjustable DC test current for determining resistances on circuit breakers or inductive loads such as transformers, for example. The high-precision ohm meters of the PROMET series are used to determine very low electrical resistances in the µΩ range. The adjustable test current of up to 600 A in combination with a four-wire measuring method delivers measurement results which meet stringent accuracy requirements. State-of-the-art power electronics coupled with a robust design guarantee excellent reliability for use as a portable device in switching stations and industrial environments. Typical applications include determining the contact resistance of switchgear devices and determining the resistance on inductive loads such as transformers.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • Transformer Test Equipment

    IBEKO Power AB

    DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.

  • Instrument Transformer

    NEO TELE-TRONIX PVT. LTD

    Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.

  • Fully Automatic Transformer Winding Resistance Tester

    Neutronics Manufacturing Co.

    Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.

  • 10 A portable digital micro-ohmmeter

    MPK-253 - MEGABRAS srl

    The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.

  • Current Transformer Tester

    CT-T1 - Raytech AG

    The CT-T1 is a microprocessor-based Current Transformer Tester that measures CT excitation current, turns ratio, and winding polarity tests, all without having to switch the leads during testing. The instrument has a fully automatic knee point detection (ASA 10/50, IEEE 30°, IEEE 45°). Although includes 5 low side taps and 1 high side tap.

Get Help